De-dusting unit for a clinker cooler
Sales contact person
Our latest development for Portland Zementwerke Gebr. Seibel GmbH & Co KG in the field of de-dusting and filtering engineering concerns a de-dusting solution for clinker coolers. The unit is designed to cope with an air volume amounting to 280,000m3/h.
It consists of a bag chamber filter system of Type: SK60/4.5m-XXIV of double row with 12 chambers in each row. A small challenge marked the assembly of the unit at a height of over 20 metres.
Technical details of the project
- This filter plant consists of a double row filter each with 12 chamber
- In each chamber there are 60 filter bags each 4.5 metres in length
- The total number of filter bags amount therefore to 1,440
- The filtered air capacity comes to 280.000m3/h
- The filter tubes have a total surface area of 2,800m2
- The residual dust content is < 10 mg
- The complete project comprised the actual de-dusting unit including the piping and the assembly of the unit on site
Please contact Dirk Freye or Thorsten Kubea for more information.